Consultation > Par auteur > Ansari Omar

Photovoltaic generator connected to the electric grid: Comparative study of data from the sites of Rabat and Meknes (Morocco)
Abdelghani Koukouch  1, *@  , Mohamed Asbik  1, *@  , Abdellah Bah  2@  , Omar Ansari  2@  
1 : Equipe de Matériaux et Energies Renouvelables  (EMER)
URAC08, Faculté des Sciences, UMI, BP11201, Zitoune, Meknès -  Maroc
2 : Equipe de Recherche en Thermique, Energie et Environnement  (ERTEE)
l'Ecole Normale Supérieure d'Enseignement Technique RABAT (ENSET), B.P. 6207 Rabat-Instituts Rabat -  Maroc
* : Auteur correspondant

In this paper, a photovoltaic generator connected to an electric grid is considered. A comparative study between results obtained from two different PV plants (Meknès and Rabat sites), during specific days of April 2016, has been conducted. The influence of cells temperature on the electric power injected into the electric grid is highlighted. Cells temperature of Meknès site PV plant is generally higher than that of Rabat along the period of solar illumination. Thus during the month of April 2016, the electric power injected by the photovoltaic cell plant of Rabat site (361.46 kWh) is higher than that of Meknes site (341.30 kWh).


Personnes connectées : 4